Welding System User Manual
Page  13
Section 3 – Installation
Dukane Manual Part No. 403-577-01
Power Cords
200/240 Volt Systems
The IEC AC  power  inlet  connector mounted on the rear 
panel requires a properly congured IEC compliant power 
cord.
The 200/240 AC power cords supplied with the 
generators are matched to the ultrasonic output power 
rating and the continent of specied use. See Table 3-I.
Table 3-  I Standard IEC AC Power Cord Part Numbers
100/120 Volt Systems (North America or Japan)
The power cord (including strain relief) supplied with the 
100/120 AC systems is permanently attached to the rear 
of the generator. Units with this power cord are for use in 
North America or Japan.
HAND PROBE Connector
Ultrasound Output
The ultrasound output connector used with this generator 
is integrated into a D-Sub style connector. This connector 
provides superior shielding of electrical noise. The output 
connector  mates  with  a  fully  shielded  ultrasound  cable 
that is secured to the generator with two simple, reliable 
thumbscrews. 
The ultrasonic output from this connector (that drives the 
attached  ultrasonic  load)  is  a  very  high AC  voltage.   At 
high power levels there is high current, and the cable must 
be securely attached to the hand probe for safe operation. 
Only  use  original  equipment  ultrasound  cables  for  safe 
and reliable system operation. 
Continent of Use Power Cord
Part Number
Power
North America 200 - 1541 240V, 10A
Europe 200 - 1542 240V, 10A
India 200 - 1624 240V, 10A