Electrical Safety
Domestic Power Grounding
For  safety,  the  power  cords  used  on  this  product  have  a 
three-wire, grounding-type power cord. Figures 2-1 and 2-
2 illustrate the appropriate electrical outlet to use with the 
power cords included with 100-120 volt and 200-240 volt 
systems respectively. This information applies to systems 
shipped to North America or Japan.
International Power Grounding
The power cable normally provided for international use 
is compatible with the power outlet used in many Conti-
nental European countries. Refer to Figure 2–3. However, 
if  your  application  requires  another  type  of  power  cord, 
check with your equipment supplier, and follow local reg-
ulations concerning proper wiring and grounding.
Figure 2–3 International 220/240V Grounding
Grounding Contacts
Typical Outlet
Provided Cable
Approved 2 pole, 3 wire grounding receptacle 
HUBBELL No. HBL 5662 or equivalent
NEMA Configuration 6–15R or 6–20R
Figure 2–2 Example of 250 Volt,   
Grounded, 3-Prong Receptacle
CAUTION
If you have a two-prong elec-
trical receptacle, we strongly 
recommend that you replace 
it with a properly grounded 
three-prong  type.  Have  a 
qualied electrician replace 
it following the National Elec-
tric Code and any local codes 
and  ordinances  that  apply.
See  Figures  2–1  and  2–2.
CAUTION
If there is any question about 
the grounding of your recep-
tacle,  have  it  checked  by 
a  qualified  electrician.  Do 
not  cut  off  the  power  cord 
grounding  prong,  or  alter 
the  plug  in  any  way.    If  an 
extension  cord  is  needed, 
use a three-wire cord that is 
in good condition. The cord 
should  have  an  adequate 
power  rating  to  do  the  job 
safely.  It  must  be  plugged 
into a grounded receptacle. 
Do not use a two-wire exten-
sion cord with this product.
Figure 2–1 Example of 125 Volt,   
Grounded, 3-Prong Plug and Receptacle
Approved 2 pole, 3 wire grounding receptacle 
HUBBELL No. HBL 5262 or equivalent
NEMA Configuration 5–15R or 5–20R