Staff/Duty Station LED Flash Rates and Tone Rates
Pending calls and reminder recalls will tone and flash the presence LEDs at staff/duty sta
-
tions and at stations where the system monitor is activated.
These charts show the default LED flash rates and tone rates for designated calls. If your
system has been configured differently, note the changes in the margins.
Note:
In the charts, “ppm” means “pulses per minute.”
4-32
ProCare 6000 Operation Manual
Staff/Duty Station LED Flash Rates and Tone Rates
Call Priority LED Flash Rate Tone Rate
Code Blue Fast (60 ppm) Very fast (240 ppm)
Staff Emergency Fast (60 ppm) Fast (60 ppm)
Lavatory Fast (60 ppm) Fast (60 ppm)
Patient Emergency Fast (60 ppm) Fast (60 ppm)
Patient Priority Slow (30 ppm) Slow (15 ppm)
Patient Normal Slow (30 ppm) Slow (15 ppm)
Chart 4-3: Staff/Duty and Monitoring Station Flash and Tone Rates
Auxiliary Call LED Flash Rate Tone Rate
Room Fast (60 ppm) Very fast (240 ppm)
AE1 Fast (60 ppm) Fast (60 ppm)
AE2 Fast (60 ppm) Fast (60 ppm)
AE3 Fast (60 ppm) Fast (60 ppm)
AE4 Fast (60 ppm) Fast (60 ppm)
AP1 Slow (30 ppm) Slow (15 ppm)
AP2 Slow (30 ppm) Slow (15 ppm)
AP3 Slow (30 ppm) Slow (15 ppm)
Cord Slow (30 ppm) Slow (15 ppm)
Chart 4-4: Staff/Duty and Monitoring Station Flash and Tone Rates for
Auxiliary Calls