Instruction manual
Table Of Contents
- Range of Applications
- Scope of Supply
- Operation
- Putting into Service
- Setting the Basic Functions
- Functions and Settings
- First Stitch after Power On
- Softstart
- Sewing Foot Lifting
- Sewing Foot Pressure Reduction
- Start Backtack
- End Backtack
- Start and End Backtack with Switch-On and Switch-Off Delay
- Start Ornamental Backtack
- End Ornamental Backtack
- Multiple Backtacking
- Catch backtacking
- Intermediate Backtack
- Backtack Suppression/Recall
- Holding Power of the Stitch Regulator Solenoid
- Reverse Motor Rotation
- Machine Run Blockage (Safety Switch)
- Thread Monitor
- Input Signals
- Parameter 195 = 0 – No Thread Monitor Function
- Parameter 195 = 1 – Model 270 / No Stop / Sewing Foot Down after Seam End
- Parameter 195 = 2 – Model 767, N291 / With Stop / Sewing Foot Up after Seam End
- Parameter 195 = 3 – Model 767, N291 / With Stop / Sewing Foot Down after Seam End
- Parameter 195 = 4 – With Thread Monitor Stitch Counting
- Needle Cooling
- High Lift for Walking Foot
- Manual High Lift for Walking Foot – Speed Limitation
- Maximum High Lift for Walking Foot by Using a Key
- High Lift for Walking Foot Operational Mode Not Stored(Pa. 138 = OFF, Pa. 184 = 0)
- High Lift for Walking Foot Operational Mode Stored (Pa. 138 = ON)
- High Lift for Walking Foot Operational Mode Not Stored with Minimum Number of Stitches (Pa. 138 = OFF, Pa. 184 = >0)
- Speed Limitation
- Switch Stitch Length
- Roller
- Thread Clamp
- Thread Trimming Operation
- Seam with Stitch Counting
- Free Seam and Seam with Light Barrier
- Light Barrier
- Needle Up/Down / Single Stitch
- F1/F2 Function Key Assignment on the V810/V820 Control Panels
- Signal Output Position 2
- Signal Output 512 Impulses per Rotation
- Actuator
- Acoustic Signal
- Master Reset
- Input and Output Function Test
- Error Displays
- Operating Elements of the V810 Control Panel
- Operating Elements of the V820 Control Panel

EFKA DA82GA3312
9
3.2 V810 Control Panel Operation
3.2.1 Code Number Input on the V810 Control Panel
Example: Technician level CODE number selection on the V810 control panel
TURN POWER OFF
+
TURN POWER ON. First digit blinks !
Press the + or – key to select the first digit !
Press the >> key !
Second digit blinks !
Press the + or – key to select the second digit !
Press the >> key twice !
Fourth digit blinks !
Press the + or – key to select the fourth digit!
If the CODE number is correct, the first
PARAMETER number at the selected level
is displayed !
3.2.2 Parameter Input at the Operator Level on the V810 Control Panel
Example: CODE number has not been input !
TURN POWER ON !
First parameter at the operator level is
displayed.
Second parameter at the operator level is
displayed. The next or previous parameter
can be called by pressing the +/- keys.
Parameter value is displayed !
Change parameter value by pressing the
+/- keys.
Parameter value is entered.
Display advances to the next parameter.
Press the + key several times until the
desired parameter is displayed !
Parameter value is displayed !
Technician Level Code Number => 1907 and Supplier Level Code Number => 3112
P
C – 0 0 0 0
+
-
C – 1 0 0 0
» C – 1 0 0 0
+
- C – 1 9 0 0
» » C – 1 9 0 0
+
- C – 1 9 0 7
E
F – 1 0 0
d A 8 2 G A
P
F – 0 0 0
+
F – 0 0 1
E
0 0 3
+
X X X
E
F – 0 0 2
+
F – 0 0 9
E
O F F