Instruction manual
Table Of Contents
- Range of Applications
- Scope of Supply
- Operation
- Putting into Service
- Setting the Basic Functions
- Functions and Settings
- First Stitch after Power On
- Softstart
- Sewing Foot Lifting
- Sewing Foot Pressure Reduction
- Start Backtack
- End Backtack
- Start and End Backtack with Switch-On and Switch-Off Delay
- Start Ornamental Backtack
- End Ornamental Backtack
- Multiple Backtacking
- Catch backtacking
- Intermediate Backtack
- Backtack Suppression/Recall
- Holding Power of the Stitch Regulator Solenoid
- Reverse Motor Rotation
- Machine Run Blockage (Safety Switch)
- Thread Monitor
- Input Signals
- Parameter 195 = 0 – No Thread Monitor Function
- Parameter 195 = 1 – Model 270 / No Stop / Sewing Foot Down after Seam End
- Parameter 195 = 2 – Model 767, N291 / With Stop / Sewing Foot Up after Seam End
- Parameter 195 = 3 – Model 767, N291 / With Stop / Sewing Foot Down after Seam End
- Parameter 195 = 4 – With Thread Monitor Stitch Counting
- Needle Cooling
- High Lift for Walking Foot
- Manual High Lift for Walking Foot – Speed Limitation
- Maximum High Lift for Walking Foot by Using a Key
- High Lift for Walking Foot Operational Mode Not Stored(Pa. 138 = OFF, Pa. 184 = 0)
- High Lift for Walking Foot Operational Mode Stored (Pa. 138 = ON)
- High Lift for Walking Foot Operational Mode Not Stored with Minimum Number of Stitches (Pa. 138 = OFF, Pa. 184 = >0)
- Speed Limitation
- Switch Stitch Length
- Roller
- Thread Clamp
- Thread Trimming Operation
- Seam with Stitch Counting
- Free Seam and Seam with Light Barrier
- Light Barrier
- Needle Up/Down / Single Stitch
- F1/F2 Function Key Assignment on the V810/V820 Control Panels
- Signal Output Position 2
- Signal Output 512 Impulses per Rotation
- Actuator
- Acoustic Signal
- Master Reset
- Input and Output Function Test
- Error Displays
- Operating Elements of the V810 Control Panel
- Operating Elements of the V820 Control Panel

EFKA DA82GA3312
8
3 Operation
3.1 Access Authorization upon Command Input
In order to prevent unintentional changes of preset functions the command input is distributed at various levels.
The following persons have access: - the supplier to the highest and all subordinate levels using a code number
- the technician to the next lower and all subordinate levels using a code
number
- the operator to the lowest level without using a code number
ACaCCallufruf
Call-up
Supplier: Code number for the
control panel is
3112
Supplier Level
200 series of
parameter numbers
Technician: Code number for the
control panel is
1907
Technician Level
100 series of
parameter numbers
Operator Level