Instruction manual
Table Of Contents
- Range of Applications
- Scope of Supply
- Operation
- Putting into Service
- Setting the Basic Functions
- Functions and Settings
- First Stitch after Power On
- Softstart
- Sewing Foot Lifting
- Sewing Foot Pressure Reduction
- Start Backtack
- End Backtack
- Start and End Backtack with Switch-On and Switch-Off Delay
- Start Ornamental Backtack
- End Ornamental Backtack
- Multiple Backtacking
- Catch backtacking
- Intermediate Backtack
- Backtack Suppression/Recall
- Holding Power of the Stitch Regulator Solenoid
- Reverse Motor Rotation
- Machine Run Blockage (Safety Switch)
- Thread Monitor
- Input Signals
- Parameter 195 = 0 – No Thread Monitor Function
- Parameter 195 = 1 – Model 270 / No Stop / Sewing Foot Down after Seam End
- Parameter 195 = 2 – Model 767, N291 / With Stop / Sewing Foot Up after Seam End
- Parameter 195 = 3 – Model 767, N291 / With Stop / Sewing Foot Down after Seam End
- Parameter 195 = 4 – With Thread Monitor Stitch Counting
- Needle Cooling
- High Lift for Walking Foot
- Manual High Lift for Walking Foot – Speed Limitation
- Maximum High Lift for Walking Foot by Using a Key
- High Lift for Walking Foot Operational Mode Not Stored(Pa. 138 = OFF, Pa. 184 = 0)
- High Lift for Walking Foot Operational Mode Stored (Pa. 138 = ON)
- High Lift for Walking Foot Operational Mode Not Stored with Minimum Number of Stitches (Pa. 138 = OFF, Pa. 184 = >0)
- Speed Limitation
- Switch Stitch Length
- Roller
- Thread Clamp
- Thread Trimming Operation
- Seam with Stitch Counting
- Free Seam and Seam with Light Barrier
- Light Barrier
- Needle Up/Down / Single Stitch
- F1/F2 Function Key Assignment on the V810/V820 Control Panels
- Signal Output Position 2
- Signal Output 512 Impulses per Rotation
- Actuator
- Acoustic Signal
- Master Reset
- Input and Output Function Test
- Error Displays
- Operating Elements of the V810 Control Panel
- Operating Elements of the V820 Control Panel

EFKA DA82GA3312
51
Functions Parameter
Speed stage graduation (nSt) 119
The pedal characteristics (speed change from stage to stage) can be varied.
Possible characteristic curves: - linear
- progressive
- highly progressive
6.33 Acoustic Signal
Functions Parameter
Acoustic signal when machine run blockage or thread monitor is On (AkS) 127
An acoustic signal which sounds in the following cases can be enabled using parameter 127:
Parameter 127 = 0 Acoustic signal Off.
Parameter 127 = 1 Acoustic signal from stop after execution of the stitches to pressing key 8.
Parameter 127 = 2 The drive stops after execution of the stitches. Sewing is possible up to the seam end. Then
the acoustic signal sounds until key 8 is pressed.
Parameter 127 = 3 The drive stops after execution of the stitches, and the acoustic signal sounds 5 times. Sewing
is possible up to the seam end. Then the acoustic signal sounds until key 8 is pressed.
6.34 Master Reset
Recovery of factory settings.
Press the "P" key and turn power on
Input code number "190"
Press the "E" key
Parameter 100 appears on the display
Press the "E" key
The parameter value is shown on the display
Set to "170" using the “+” key
Press the "P" key twice
Turn power off
Turn power on. All parameters, except 111, 161, 170, 171, 190...194, have been reset to their factory settings.