Instruction manual
Table Of Contents
- Range of Applications
- Scope of Supply
- Operation
- Putting into Service
- Setting the Basic Functions
- Functions and Settings
- First Stitch after Power On
- Softstart
- Sewing Foot Lifting
- Sewing Foot Pressure Reduction
- Start Backtack
- End Backtack
- Start and End Backtack with Switch-On and Switch-Off Delay
- Start Ornamental Backtack
- End Ornamental Backtack
- Multiple Backtacking
- Catch backtacking
- Intermediate Backtack
- Backtack Suppression/Recall
- Holding Power of the Stitch Regulator Solenoid
- Reverse Motor Rotation
- Machine Run Blockage (Safety Switch)
- Thread Monitor
- Input Signals
- Parameter 195 = 0 – No Thread Monitor Function
- Parameter 195 = 1 – Model 270 / No Stop / Sewing Foot Down after Seam End
- Parameter 195 = 2 – Model 767, N291 / With Stop / Sewing Foot Up after Seam End
- Parameter 195 = 3 – Model 767, N291 / With Stop / Sewing Foot Down after Seam End
- Parameter 195 = 4 – With Thread Monitor Stitch Counting
- Needle Cooling
- High Lift for Walking Foot
- Manual High Lift for Walking Foot – Speed Limitation
- Maximum High Lift for Walking Foot by Using a Key
- High Lift for Walking Foot Operational Mode Not Stored(Pa. 138 = OFF, Pa. 184 = 0)
- High Lift for Walking Foot Operational Mode Stored (Pa. 138 = ON)
- High Lift for Walking Foot Operational Mode Not Stored with Minimum Number of Stitches (Pa. 138 = OFF, Pa. 184 = >0)
- Speed Limitation
- Switch Stitch Length
- Roller
- Thread Clamp
- Thread Trimming Operation
- Seam with Stitch Counting
- Free Seam and Seam with Light Barrier
- Light Barrier
- Needle Up/Down / Single Stitch
- F1/F2 Function Key Assignment on the V810/V820 Control Panels
- Signal Output Position 2
- Signal Output 512 Impulses per Rotation
- Actuator
- Acoustic Signal
- Master Reset
- Input and Output Function Test
- Error Displays
- Operating Elements of the V810 Control Panel
- Operating Elements of the V820 Control Panel

EFKA DA82GA3312
42
Press key E. New value 17 (lower break point)
is entered.
Press key P once. Display of the actual parameter
number.
or
Press key P twice. Exit programming.
These values are saved when you start sewing. They remain in effect even after turning the machine off!
Note
If you set a value on the potentiometer, which is between the actual break points, both values will be overwritten when
pressing key E. Only after that is it possible to program new lower and/or upper break point values.
6.21 Switch Stitch Length
Functions Parameter
Number of light barrier compensating stitches for long stitches (LS) 004
Number of light barrier compensating stitches for short stitches (cLS) 010
High lift walking speed (DB2000) (n10) 117
Stitch length during backtack: normal stitch / long stitch (SLu) 137
Normal stitch / long stitch with speed limitation (key on A/8 and D/2) (StL) 145
1 = without speed limitation
2 = with DB2000
3 = with DB3000
Stitch length in the next seam (after the trimming operation) (Stn) 187
Speed limitation (DB3000) (n11) 289
When the key connected to socket A/8-33 or D/2-15 is pressed, the stitch length can be reduced to a smaller value by
enabling the output “switch stitch length“ (LED Off). When the key is pressed again, the stitch length is switched. This
function can be enabled or disabled at any time, except in automatic seams and seam sections. Sewing is possible without
speed limitation, with speed limitation DB2000 or DB3000 depending on the setting of parameter 145.
The compensating stitches for light barrier seams are set at the operator level using parameter 004 or 010.
The start or end backtack stitch length is set using the following parameter:
Parameter 137 = ON The backtack is performed with normal stitches.
Parameter 137 = OFF The backtack is performed with long stitches.
The light emitting diodes do not flash when switching the stitch length by means of autoselect in the start or end backtack.
The stitch length with which the next seam after trimming will be performed can be selected using parameter 187.
Parameter 187 = 1 The selected stitch length remains On.
Parameter 187 = 2 Switch to long stitches after thread trimming.
Parameter 187 = 3 Switch to normal stitches after thread trimming.
After power On, normal stitches are automatically enabled (solenoid On, LED Off).
6.22 Roller
Functions Parameter
Roller function on key on socket D/4 (mFd) 146 = 3
Roller function on key on socket D/3 (Fc3) 147 = 3
Roller function on key on socket D/6 (Fc6) 149 = 3
Stitches until roller lowering (ctw) 186
Stitch delay after lowering the sewing foot until roller lowering On/Off (PLc) 260
Roller lifting depending on sewing foot and backtack (FLk) 261
When enabling high lift for walking foot, roller remains lowered/lifted (hPt) 262
E
0 8 1 7
P
F - 1 8 2
P
d A 8 2 G A
P