6.10 Multiple Backtacking
Functions Parameter
Repetitions of double start backtacking (wAR) 090
Repetitions of double end backtacking (wER) 091
Multiple backtacking is possible only if double start or end backtacking is On. (Value 0 = Multiple backtacking Off).
Sewing direction
¬ ®
¬
Catch backtacking
Normal backtacking
®
Multiple backtacking
6.11 Catch backtacking
Functions Parameter
Number of catch backtacking stitches forward (cb1) 092
Number of catch backtacking stitches backward (cb2) 093
Catch backtacking is possible only at the start of the seam if double start backtacking is On, not with start ornamental
backtacking (Value 0 = Catch backtacking Off). The catch backtacking function is active only if parameter 093 > 0.
Sewing direction
¬ ®
¬
Catch backtacking
Normal backtacking
®
Multiple backtacking
6.12 Intermediate Backtack
Upon pressing an external key on socket A/5-33 or C/1-2, the backtack solenoid can be enabled anywhere in the seam. The
speed limitation of parameter 288 or 289 becomes effective according to the setting of parameters 135 and 287. See List of
Parameters chapter Connection Diagram!
Function Parameter
Intermediate backtack, function of the key on socket D/5 (Fc5) 148 = 2
Speed limitation DB3000 for manual backtack On/Off (dbA) 287
Speed limitation for manual ornamental backtack (n9) 288
Speed limitation for manual backtack (n11) 289
Intermediate backtack:
Backward sewing with speed limitation according to the setting of parameter 289 is performed when the key is pressed
down.