Instruction manual

Table Of Contents
EFKA DA82GA3312
12
3.4 Program Identification
Function Parameter
Program number, modification index and identification number display 179
Display example parameter 179 on the V810 control panel:
Select parameter 179!
Press the E key e. g. 3312A is displayed (Program number with index)
Press the >> key e. g. 011105 is displayed (Identification number)
Press the P key twice dA82GA is displayed (Sewing process can be started)
Display example parameter 179 on the V820 control panel:
Select parameter 179!
Press the E key 312A 01110535 is displayed (Program number shortened by one
digit with index and identification
number)
Press the P key twice 4000 dA82GA is displayed (Sewing process can be started)
3.5 Direct Input of Maximum Speed Limitation (DED) with Control Panel
The maximum speed of the machine must be limited to the specific level according to the application. Do the setting at the
operator level using the +/- keys after each seam end. The actual value is shown on the display. The speed setting range is
between parameter 111 (upper limit) and parameter 121 (lower limit).
3.5.1 Setting on the V810 Control Panel
Type designation is displayed
Maximum speed is displayed
(reading remains on for max. 5 seconds)
Change the value;
e. g. press the key 8 times !
After approx. 5 seconds the display shows
3.5.2 Setting on the V820 Control Panel
Actual display value at the operator level
Maximum speed and type designation are displayed
Change the maximum speed value;
e. g. press the key 8 times !
This value is saved when you start sewing. It remains in effect even after turning the machine off!
d A 8 2 G A
+
4 0 0 0
+
- 3 2 0 0
d A 8 2 G A
4000 dA82GA
+
- 3200 dA82GA
Note
Changing the setting of the maximum speed limitation also affects the start backtack, end backtack and stitch
counting speeds.