Instruction manual

Table Of Contents
EFKA DA82GA3312
10
New parameter value is displayed !
Next parameter is displayed !
or
Exit programming !
These values are saved when you start sewing. They remain in effect even after turning the machine off!
3.2.3 Parameter Input at the Technician/Supplier Level on the V810 Control Panel
Example: After CODE number input at the technician level.
After CODE number input, the first
PARAMETER number is displayed!
Press the + key ! The next
parameter number is displayed !
Press key E!
The parameter value is displayed !
Change the parameter value !
Parameter value is entered.
Display advances to the next parameter.
or
Parameter value is entered.
The actual PARAMETER number is displayed!
or
Press key P twice !
Exit programming !
These values are saved when you start sewing. They remain in effect even after turning the machine off!
3.3 V820 Control Panel Operation
3.3.1 Code Number Input on the V820 Control Panel
Example: Technician level CODE number selection on the V820 control panel
TURN POWER OFF !
+
TURN POWER ON !
Input CODE number !
+
O N
Note!
The parameter number can also be selected directly, like the code number!
F – 1 0 0
+
F – 1 1 0
E
0 1 8 0
+
- 0 X X X
E
F – 0 1 0
P
d A 8 2 G A
E
F – 1 1 1
P
F - 1 1 0
P
P
d A 8 2 G A
Technician Level Code Number => 1907 and Supplier Level Code Number => 3112
P
C–0000
1
9
C–1907
0
7