Operating instructions

Set-up instructions
44 Operating manual H867 Version 00.0 - Last updated: 01/2012
8.15.2 Setting the operating pressure
Figure 49: Setting the operating pressure
Pull the turning handle (1) up.
Set the operating pressure in such a way that the pressure
indicator (2) indicates 6 bar:
To increase the pressure:
Turn the turning handle (1) clockwise.
To reduce the pressure:
Turn the turning handle (1) counterclockwise.
Push the turning handle (1) down.
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
The operating pressure for the pneumatic unit is 6 bar.
Make sure that the operating pressure is set correctly before putting
the machine into operation.
ATTENTION
0
2
8
4
6
10
w
q
(1) - Turning handle
(2) - Pressure indicator