Operating instructions
Set-up instructions
44 Operating manual H867 Version 00.0 - Last updated: 01/2012
8.15.2 Setting the operating pressure
Figure 49: Setting the operating pressure
• Pull the turning handle (1) up.
• Set the operating pressure in such a way that the pressure
indicator (2) indicates 6 bar:
To increase the pressure:
Turn the turning handle (1) clockwise.
To reduce the pressure:
Turn the turning handle (1) counterclockwise.
• Push the turning handle (1) down.
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
The operating pressure for the pneumatic unit is 6 bar.
Make sure that the operating pressure is set correctly before putting
the machine into operation.
ATTENTION
0
2
8
4
6
10
w
q
(1) - Turning handle
(2) - Pressure indicator