Operating instructions

Operating instructions
32 Operating manual H867 Version 00.0 - Last updated: 01/2012
Water condensation may accumulate in the water separator of the pressure
controller.
Figure 30: Water level in the pressure controller
Check the water level every day:
The condensation water must not rise up to the level of the filter
element (1).
Drain water as required:
Switch off the sewing machine at the main switch.
Place the collection tray under the drain screw (3).
Unscrew the drain screw (3) completely.
Allow water to drain into the collection tray.
Re-tighten the drain screw (3).
Switch on the sewing machine at the main switch.
7.17 Repairs
Contacts for repair in the event of damage to the machine:
Dürkopp Adler AG
Potsdamer Str. 190
33719 Bielefeld, Germany
Tel. +49 (0) 180 5 383 756
Fax +49 (0) 521 925 2594
E-mail: service@duerkopp-adler.com
Internet: www.duerkopp-adler.com
0
2
8
4
6
10
w
e
q
(1) - Filter element
(2) - Water separator
(3) - Drain screw
Machine damage possible if there is too much water.
Too much water can cause damage to the machine.
Check the water level every day and drain condensation water if
there is too much water in the water separator.
ATTENTION