Oil to be used:
Only DA 10 or an oil of equivalent quality may be used for the machine,
which has the following properties:
• Viscosity at 40° C: 10 mm²/s
• Flash point: 150° C
7.16.3 Checking the pneumatic system
Figure 29: Pressure indication in the pressure controller
Check the pressure at the pressure indicator (1) every day:
• Reference value: 6 bar.
• The pressure must not deviate from the reference pressure by more
than 1 bar.
Machine damage possible due to incorrect oil.
An incorrect oil type can cause damage to the machine.
Only use oil that complies with the data in the operating manual.
ATTENTION
0
2
8
4
6
10
w
q
(1) - Reference value: 6 bar
(2) - Pressure indicator
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
Check the pressure on a daily basis.
Have the pressure adjusted by qualified specialists in accordance
with the information in the service manual if the pressure deviates
from the reference value.