Instruction manual
EFKA AB221A/AB321A + AB222A/AB322A (BA)
96
12 Error Displays
General Information
On the control On the V810 On the V820 Signification
A1 InF A1 InF A1 Pedal not in neutral position when turning the
machine on
A2 -StoP- blinking -StoP- blinking + Machine run blockage
symbol display
A3 InF A3 InF A3 Reference position is not set
A6 InF A6 InF A6 Light barrier monitoring
A7 Symbol blinking Symbol blinking Bobbin thread monitor
A500 FileFl File Full Max. number of files (99) on Memory Stick
exceeded
A501 noFile noFile File not found on Memory Stick
A503 not EQ not EQ Data on Memory Stick and in the control is
not equal
On the control On the V810 On the V820 Signification
C1 InF C1 InF C1 The operating hours counter has reached or
exceeded the service time
Programming Functions and Values (Parameters)
On the control On the V810 On the V820 Signification
Returns to 0000 Returns to Like V810 + Wrong code or parameter number input
or to last 0000 or to last display InF F1
parameter number parameter
number
Serious Condition
On the control On the V810 On the V820 Signification
E1 InF E1 InF E1 The external pulse encoder e.g. IPG... is
defective or not connected.
E2 InF E2 InF E2 Line voltage too low, or time between power
Off and power On too short.
E3 InF E3 InF E3 Machine blocked or does not reach the desired
speed.
E4 InF E4 InF E4 Control disturbed by deficient grounding or
loose contact.
E9 InF E9 InF E9 Defective EEPROM.