9.39 Handwheel Rotation by Keystroke
Function with or without control panel Parameter
Number of handwheel rotation steps (increments) triggered by keystroke (ihr) 260
Speed of handwheel rotation triggered by keystroke (nhr) 261
Delay time until the key is pressed down causing the handwheel to rotate continuously (ihP) 262
The handwheel can be set in motion by pressing a key. Select the input (in1…i10) used for this function and the direction
of rotation using parameters 240...249.
240...249 = 20 Direction of rotation corresponds to that of the machine.
240...249 = 21 Direction of rotation is opposite to that of the machine.
260 - Number of steps by which the handwheel rotates upon keystroke.
261 - Speed of handwheel rotation triggered by keystroke.
262 - Delay time until the key is pressed down causing the handwheel to rotate continuously
When the key is pressed briefly, i.e. no longer than the time set using parameter 262, the handwheel rotates by the steps set
using parameter 260.
When the key is held down, the handwheel rotates continuously until the key is released.
The handwheel rotates at the speed set using parameter 261.
9.40 Speed Limitation by means of External Potentiometer
Function with or without control panel Parameter
Speed limitation by means of external potentiometer (maximum value) (toP) 124
Speed limitation by means of external potentiometer (minimum value) (bot) 125
Function “speed limitation with external potentiometer” (Pot) 126
The functioning of the speed limitation when using an external potentiometer can be selected using parameter 126.
The desired limitation speed is set using a potentiometer connected to socket ST2/2-4. The maximum/minimum value of
speed limitation is set using parameters 124/125.
124: Maximum value for speed limitation with external potentiometer
125: Minimum value for speed limitation with external potentiometer
126 = 0 Function “external potentiometer” Off.
126 = 1 The external potentiometer is active whenever the pedal is pressed forward. The drive always runs with the set
speed limitation.
126 = 2 The external potentiometer is active only if an input is set at "25" by means of parameters 240...249. If the
selected input is enabled and the pedal pressed forward, the drive runs at limited speed. The speed limitation can
be enabled and disabled anywhere in the seam using the key.
126 = 3 Speed depending on high lift with potentiometer e.g. Juki (LU-2210/2260).
126 = 4 Speed depending on high lift with potentiometer e.g. Dürkopp Adler (767).
9.41 Signals A1 and A2
When using the V820 control panel, direct access by means of the function key (key 9) is possible!
Function with control panel Parameter
Signal A1 and/or A2 On/Off with slide-in strip 1...4 (-F-) 008 = 5
(left-hand arrow = A1, right-hand arrow = A2)
Function with control panel V820
Signal A1 On left-hand arrow above key On Key 8
Signal A2 On right-hand arrow above key On
Signals A1 and A2 On both arrows above key On
Signals A1 and A2 Off both arrows above key Off