Function with control panel V820
Stitch counting On/Off Key 2
9.33.1 Number of Stitches for a Seam with Stitch Counting
Function with or without control panel Parameter
Number of stitches for a seam with stitch counting (Stc) 007
The number of stitches for stitch counting can be set using parameter 007 directly on the control or on a connected
V810/V820 control panel.
For fast operator information (HIT) when using the V820 control panel, the value of the function switched on using key 2
can be displayed for approx. 3 seconds. During this time, the value can be varied directly by pressing key +/-.
9.33.2 Stitch Counting Speed
Function with or without control panel Parameter
Positioning speed (n1) 110
Stitch counting speed (n12) 118
Speed mode for a seam with stitch counting (SGn) 141
Activation of speed n12 when key is open/closed (ktS) 266
Speed control for stitch counting can be selected using parameter 141.
141 = 0 Execution at pedal controlled speed.
141 = 1 Execution at fixed speed n12, when pressing the pedal forward (position >1).
141 = 2 Execution at limited speed n12, when pressing the pedal forward (position >1).
141 = 3 Automatic execution at fixed speed after having pressed the pedal once. The procedure can be interrupted by
“heelback (-2)".
141 = 4 Automatic execution at fixed speed after having pressed the pedal once. The procedure can be interrupted by
“heelback (-2)".
266 = 0 Speed n12 is activated when key is closed.
266 = 1 Speed n12 is activated when key is open.
The sewing speed is reduced in each stitch depending on the actual speed (max. 11 stitches before the end of stitch
counting), in order to be able to stop exactly at the end of counting. When the light barrier is on, free sewing will be
performed after stitch counting.
9.33.3 Seam with Stitch Counting When Light Barrier Is On
Function with or without control panel Parameter
Light barrier On/Off (LS) 009
Stitch counting On/Off (StS) 015
Function with control panel V820
Light barrier On/Off Key 3
Stitch counting On/Off Key 2
When "stitch counting and light barrier function" is set, the number of stitches will be executed first, then the light barrier