Function “Blow Fabric onto Stack”
Function with or without control panel Parameter
Function “blow fabric onto stack” (bLA) 194
ON period for output M7 (kt5) 289
194 = 0 Blow fabric onto stack (output M7) at the seam end over the time (kt5), which can be set using parameter 289.
194 = 1 Blow fabric onto stack (output M7) from light barrier uncovered to seam end; after the seam end over the time
(kt5).
See also chapter “Timing Diagrams“ in the List of Parameters.
9.30 Manual Tape Cutter/Fast Scissors
Upon pressing an external key depending on the pre-selection of parameters 240...249, the tape cutter or fast scissors can
be enabled anywhere in the seam or at standstill.
See also chapter "Connection Diagram" in the List of Parameters!
9.31 Manual Stacker
Function with or without control panel Parameter
Stacker function with open/closed key (iS1) 264
ON period for manual stacker (ktS) 265
After pressing the key that has been allocated for the purpose, a stacker signal will be issued for a certain period of time
(parameter 265) at output M7 (socket ST2/23). Select the key using one of parameters 240...249. The manual stacker
function is possible in all modes except mode 16.
240...249 = 26 Allocation of the key for the manual stacker signal.
264 = 0 Signal “manual stacker” (output M7), when key is closed.
264 = 1 Signal, “manual stacker” (output M7), when key is open.
265 ON period of manual stacker signal.
9.32 Selection of Signals M8, M9 and M10 at the Start of the Seam
Function with or without control panel Parameter
Signals M8, M9, M10 On/Off (0 = Off / 1 = On) (ASi) 273
Delay time for signal M8 at the start of the seam (Ad1) 274
Signal M8 ON period at the start of the seam (At1) 275
Delay time for signal M9 at the start of the seam (Ad2) 276
Signal M9 ON period at the start of the seam (At2) 277
Delay time for signal M10 at the start of the seam (Ad3) 278
Signal M10 ON period at the start of the seam (At3) 279
Three different signals (M8, M9, M10) can be programmed for various applications at the start of the seam. These can be
enabled and disabled using parameter 273. Select delay times and ON periods using parameters 274...279.
9.33 Seam with Stitch Counting
Function without control panel Parameter
Stitch counting On/Off 015