Instruction manual
EFKA AB221A/AB321A + AB222A/AB322A (BA)
71
Tape cutter function when output M6 is disabled:
At the start of the seam, the tape cutter will be activated for the time (kt4) after a number of stitches (c7) that can be set
by means of parameter 257.
After light barrier sensing, the tape cutter will be activated for the time (kt4) at the seam end after a number of stitches
(c8) that can be set by means of parameter 258.
At standstill of the drive the tape cutter operation (double tape cutting) can be repeated any number of times by
pressing the key (setting parameter 244 = 15) connected to socket ST2/5.
See also chapter “Timing Diagrams“ in the List of Parameters.
9.29.4 Tape Cutter/Fast Scissors in Mode 16
Function without control panel Parameter
Count c1 On/Off LED 1/2 Key S2
Counts c3 and c4 On/Off LED 3/4 Key S3
Functions of sewing foot lifting On/Off LED 5/6 Key S4
Basic position 1 or 2 LED 7/8 Key S5
The signal tape cutter/fast scissors can be set separately for start and end counting.
The V810 control panel cannot be used if parameter 290 = 16 (mode 16).
When using the V820 control panel, parameter 292 will automatically be set to slide-in strip "7" if 290 = 16.
Function with control panel V820
Tape cutter/Fast scissors at the start of the seam On/Off Key 1
Tape cutter/Fast scissors at the seam end On/Off Key 2
Light barrier On/Off Key 3
Chain suction On/Off Key 4
Blow fabric onto stack from light barrier uncovered onwards On/Off Key 5
Tape cutting at the seam end On/Off Key 6
Reverse motor rotation On/Off Key 7
Unlocking the chain On/Off Key 8
Sewing foot in the seam and/or at the seam end On/Off Key 9
Basic position 1 or 2 Key 0
The settings of key 7 and 8 on the V820 control panel have priority over the setting of parameter 019.
Functions Key 2 Key 6
Tape cutting at the seam end Off, count c4 until stop Off Off
Tape cutting at the seam end On, count c4 until stop On Off
Tape cutting at the seam end Off, count c3 until stop On/Off On
Output and Times for Tape Cutter
Function with or without control panel Parameter
Delay time for output M3 (ST2/27) tape cutter AH (kd3) 284
ON period for output M3 (ST2/27) tape cutter AH (kt3) 285
Parameter 232 must be set at "0" (tape cutter function).
The delay time for the tape cutter is usually set at "0".
Output and Times for Fast Scissors
Function with or without control panel Parameter
Delay time for output M3 (ST2/27) fast scissors AH1 (kd3) 284
ON period for output M3 (ST2/27) fast scissors AH1 (kt3) 285
Delay time for output M8 (ST2/24) fast scissors AH2 (kd4) 286
ON period for output M8 (ST2/24) fast scissors AH2 (kt4) 287
Selection of signal M8 functions (m08) 296
Parameter 232 must be set at "1" (fast scissors function).
The delay times for "fast scissors" are usually set at "0".