Instruction manual
EFKA AB221A/AB321A + AB222A/AB322A (BA)
51
The following settings are possible with parameter 236:
236 = 0 Sewing foot lifting is possible from all positions.
236 = 1 Sewing foot lifting is possible only from position 2.
236 = 2 Sewing foot lifting is stored in pedal position –1 or –2. The storing can be undone by pressing the pedal
slightly forward.
See List of Parameters chapter "Timing Diagrams"!
9.4 Start Backtack/Start Stitch Condensing
Function without control panel Control
Single start backtack LED 1 On Key S2
Double start backtack LED 2 On
Start backtack Off both LEDs Off
Start stitch condensing On; number of stitches with stitch regulator LED 1 On Key S2
(parameter 001)
Start stitch condensing On; number of stitches without stitch LED 2 On
regulator
(parameter 000), after that number of stitches with stitch regulator
(parameter 001)
Start stitch condensing Off both LEDs Off
Function with control panel V810/V820
Single start backtack left-hand arrow above key On Key 1
Double start backtack right-hand arrow above key On
Start backtack Off both arrows Off
Start stitch condensing On; number of stitches with stitch regulator left-hand arrow above key On Key 1
(parameter 001)
Start stitch condensing On; number of stitches without stitch right-hand arrow above key On
regulator
(parameter 000), after that number of stitches with stitch regulator
(parameter 001)
Start stitch condensing Off both arrows Off
The start backtack/start stitch condensing starts by pressing the pedal forward at the beginning of the seam. From lifted
sewing foot the backtack is delayed by the time t3 (start delay after switching off the sewing foot lift signal). Start backtack
as well as start stitch condensing are executed automatically at speed n3. They cannot be interrupted. If softstart is running
parallel, the respective lower speed is prevailing. If backtack synchronization (parameter 298) is off, the stitch regulator
will be synchronized to position 1. The stitch regulator will be switched off after completion of the stitch count (parameter
001) and the speed n3 after a delay time t1. Then pedal control is returned. Counting is synchronized to position 1.
9.4.1 Speed n3 at the Start of the Seam
Function with or without control panel Parameter
Start backtack/start stitch condensing speed (n3) 112
Start backtack/start stitch condensing speed can be interrupted by pedal in pos. 0 (neutral) (n2A) 162
Start and end backtack or stitch condensing can be interrupted by pedal in pos. 0 (neutral) (StP) 164
On/Off
When programming 3-digit or 4-digit parameter values on the control, the 2-digit or 3-digit values displayed must be
multiplied by 10.