Functions Parameter
Call-up of the Fast Installation Routine SIR (Sir) 500
Setting on the V810 control panel:
Input code number 3112!
Press the E key The lowest parameter 2.0.0. appears at this level
Select 500 Parameter 5.0.0. is displayed
Press the E key Character [o] appears blinking
Press the >> key Parameter 2.9.0. appears (functional sequence “trimming operations”)
Press the E key Parameter value 05 appears
Press the +/- key Parameter value can be changed
Press the E key Parameter 1.6.1. appears (direction of motor rotation)
Press the E key Parameter value 1 appears
Press the +/- key Parameter value can be changed
Press the E key Parameter 2.7.2. appears (transmission ratio)
Press the E key Parameter value 100 appears
Press the +/- key Parameter value can be changed
Press the E key
Parameter 2.7.0. appears (type of position sensor)
Press the E key Parameter value 0 appears
Press the +/- key Parameter value can be changed
Press the E key Parameter 4.5.1. appears (position 1 leading edge; position 1 trailing edge
is automatically set at 60°)
Press the E key Parameter value appears
Press the +/- key Parameter value can be changed
or turn the handwheel Set position after min. 1 rotation
Press the E key Parameter 4.5.3. appears (position 2 leading edge; position 2 trailing edge
is automatically set at 60°)
Press the E key Parameter value appears
Press the +/- key Parameter value can be changed
or turn the handwheel Set position after min. 1 rotation
Upon pressing the E key once more the program returns to parameter 290
Press the P key twice Exit SIR routine
Setting on the V820 control panel:
Input code number 3112!
Press the E key The lowest parameter 2.0.0. appears at this level
Select 500 Parameter 5.0.0.
is displayed
Press the E key Character [o] appears blinking
Press the >> key Parameter 290 FAm 05 appears (functional sequence “trimming operations”)
Press the +/- key Parameter value can be changed
Press the E key Parameter 161 drE 1. appears (direction of motor rotation)
Press the +/- key Parameter value can be changed
Press the E key Parameter 272 trr 100 appears (transmission ratio)
Press the +/- key Parameter value can be changed
Press the E key Parameter 270 PGm 0 appears (type of position sensor)
Press the +/- key Parameter value can be changed
Press the E key Parameter 451 appears (position 1 leading edge; position 1 trailing edge
is automatically set at 60°)
Press the +/- key Parameter value can be changed
or turn the handwheel Set position after min. 1 rotation
Press the E key Parameter 453 appears (position 2 leading edge; position 2 trailing edge
is automatically set at 60°)
Press the +/-
key Parameter value can be changed
or turn the handwheel Set position after min. 1 rotation
Upon pressing the E key once more the program returns to parameter 290
Press the P key twice Exit SIR routine