Instruction manual

EFKA AB221A/AB321A + AB222A/AB322A (BA)
33
6 Putting into Service
Before putting the control into service, the following must be ensured, checked and/or adjusted:
The correct installation of the drive, position transmitter and accompanying devices, if necessary
The correct selection of the trimming operation using parameter 290
If necessary, the correct adjustment of the direction of motor rotation using parameter 161
The correct selection of the functions of keys (inputs) using parameters 240...249
The setting of the transmission ratio between motor shaft and machine shaft using parameter 272
The setting of the type of position sensor using parameter 270
If necessary, the setting of the number of angular degrees after the sensor position using parameter 271
If necessary, the setting of the positions using parameter 171
(possible with all settings of parameter 270)
The correct positioning speed using parameter 110
The correct maximum speed compatible with the sewing machine using parameter 111
The setting of the remaining relevant parameters
Start sewing in order to save the set values
7 Setting and Putting into Service with the Aid of the Fast Installation
Routine (SIR)
The Fast Installation Routine (SIR) passes through all parameters necessary for programming the functional sequence and
the positions.
Input parameter 500
Parameter for functional sequence
“thread trimming operations”
Parameter for direction of motor rotation
Parameter for transmission ratio
Important! The transmission ratio should be
determined and indicated as precisely
as possible.
Parameter for type of position sensor
Parameter for position 1
Parameter for position 2
The values can be varied by pressing keys +/-. When the parameter is displayed on the V810 control panel, press the
E key once more for the value to be displayed.
With SIR you can do the most important settings for initial operation with menu prompting.
For safety reasons, the menu must be executed point by point. This ensures correct setting of all important parameters.
The setting of other parameters is not affected.
F-272
End SIR
F-451
F-453
F-270
No
P
E
E
E
E
Yes
KL2438a
F-161
F-290
F-500
Code 3112
F-200
E
E
>>
E
E