Instruction manual

EFKA AB221A/AB321A + AB222A/AB322A (BA)
19
5 Control Operation with Control Panel
5.1 Operation of the V810 Control Panel
5.1.1 Code Number Input on the V810 Control Panel
Example: Technician level CODE number selection on the V810 control panel
TURN POWER OFF.
+ TURN POWER ON. First digit blinks.
Press key + or to select the first digit.
Press key >>.
Second digit blinks.
Press key + or to select the second digit.
Press key >> twice.
Fourth digit blinks.
Press key + or to select the fourth digit.
If the CODE number is correct, the first
PARAMETER number at the selected level
is displayed.
5.1.2 Parameter Input at the Operator Level on the V810 Control Panel
Example: CODE number has not been input
TURN POWER ON.
First parameter at the operator level is
displayed.
Second parameter at the operator level is
displayed. The next or previous parameter
can be called by pressing key +/-.
Parameter value is displayed.
Change parameter value by pressing
key +/-.
Parameter value is entered.
Display advances to the next parameter.
Press key + several times until the
desired parameter is displayed.
Parameter value is displayed.
Technician Level Code Number => 1907 and Supplier Level Code Number => 3112
P
C
0 0 0 0
+
-
C
1 0 0 0
» C
1 0 0 0
+
- C
1 9 0 0
» » C
1 9 0 0
+
- C
1 9 0 7
E
F
1 0 0
A b 2 2 0 A
P
F
0 0 0
+
F
0 0 1
E
0 0 3
+
X X
X
E
F
0 0 2
+
F
0 0 9
E
0