4.3.4 Immediate Storage of All Data Changes
Functions Parameter
Immediate storage of all data changes (EEP) 401
Input code number 3112 after power On Press the E key
Input parameter 401 Press the E key
Set display from 0 to1 Press the E or P key
All data is stored!
4.4 Changing All Parameter Values at the Operator Level
All parameter values at the operator level can be changed without code number input (see List of Parameters).
Press the P key The first parameter number will be displayed
Press the E key The parameter value will be displayed
Press the + /- key The parameter value will be changed
Press the E key The next parameter will be displayed
Press the E key The parameter value will be displayed
Press the + /- key The parameter value will be changed
etc.
Press the P key twice Exit programming at the operator level
4.5 Function Switchover
Switchable functions can be changed by pressing the appropriate key. The switching state is indicated by light emjtting
diodes (LED). See above illustration!
Table: Assignment of functions to keys and LEDs
Function Key LED number
Single start backtack / Chain suction at the start of the seam E (S2) 1 = on 2 = off
Double start backtack / Chain suction at the seam end E 1 = off 2 = on
Chain suction at the start of the seam / seam end E 1 = on 2 = on
Start backtack Off / Chain suction Off E 1 = off 2 = off
Single end backtack / Tape cutter at the start of the seam + (S3) 3 = on 4 = off
Double end backtack / Tape cutter at the seam end + 3 = off 4 = on
Tape cutter at the start of the seam / seam end + 3 = on 4 = on
End backtack Off / Tape cutter Off + 3 = off 4 = off
Sewing foot lift at stop in the seam (automatic) - (S4) 5 = on 6 = off
Sewing foot lift at the seam end (automatic) - 5 = off 6 = on
Sewing foot lift at stop in the seam and at the seam end (automatic) - 5 = on 6 = on
Sewing foot lift (automatic) Off - 5 = off 6 = off
Basic position down (position 1) >> (S5) 7 = on 8 = off
Basic position up (position 2) >> 7 = off 8 = on