5.1.1 Connecting the sewing light transformer to the supply voltage
Caution Danger of Injury!
The sewing light cannot be turned off with the main switch
(EN 60 204-31)! The mains power supply must be disconnected before
mounting the illumination, repairing the transformer or changing fuses.
Pull the plug out of the socket.
Loosen the four screws on the front plate of the control c abinet.
Take off the front plate.
Guide the sewing light transformer cable through the cable duct (1)
into the control cabinet.
Take off the black rubber guide track (2).
Make a hole in the guide track (2) with a screw driver.
Guide the cable for the sewing light transformer through this new
opening.
Re-mount the rubber guide track (2).
Use a thin screwdriver to press on the terminal openings (3) and
(4). This opens up the terminals (5) and (6).
Connect the blue cable to terminal (6) and the brown cable to
terminal (5).
Screw the front plate back on.
Install a strain relief mechanism (e.g., a cable tie) for the
transformer cable.