Technical data

Set-up instructions
100 Operating manual 806N Version 00.0 - 12/2012
Figure 68: Connection to the pneumatic system
Connect the compressed air as follows:
1. Connect the connection hose with the hose coupling to the com-
pressed air supply.
2. Plug the connection hose onto the hose neck of the pressure gage
and fasten with a hose clamp.
3. Open the shut-off valve by turning it to the right into the horizontal
position.
Setting the operating pressure
The operating pressure is 6 bar. This can be read on the pressure gage
(1).
To increase
pressure
Pull the twist grip (2) down and turn it clockwise until reaching a pressure
of 6 bar.
To reduce
pressure
Pull the rotary handle (2) down and turn it counter-clockwise until reaching
a pressure of 6 bar.
6.5.5 Topping up the oil
The procedure for topping up the oil in the sewing unit is described in
Section 5.11.2 Lubrication. The specifications for the oil to be used are
also listed below.
Use only DA10 sewing machine oil or an equivalent oil conforming to the
following specifications:
Viscosity at 40°C: 10 mm
2
/s
Flash point: >160°C
DA10 sewing machine oil can be obtained from Dürkopp Adler sales
offices under the following part numbers:
(1) - Pressure gage (2) - Twist grip