Technical data
Set-up instructions
Operating manual 806N Version 00.0 - 12/2012 99
6.5.3 Electrical connection
The power cable is already installed on the machine. On delivery it lies
inside the machine. It is advisable to remove at least one of the rear covers
below the table level in order to access the power cable. A country-specific
plug must be fitted to the cable.
Rated voltage The rated voltage is specified on a second plate below the sewing unit
type plate, which is located below the main power switch. The rated volt-
age must agree with the mains voltage or major material damage to the
machine may occur.
6.5.4 Pneumatic connection
The pneumatic system for the sewing unit must satisfy the following
requirements:
• It must be supplied with moisture-free compressed air
• The supply pressure must lie between 8 and 10 bar
• Even at the moment of maximum air consumption, the supply
pressure must never drop below the minimum operating pres-
sure of 5 bar (or the machine will not function)
The connection hose for the pneumatic system is not included in the scope
of delivery of the sewing unit. It must be ordered separately.
Risk of injury from electricity.
Unprotected contact with electricity can result in
serious injuries or death.
Work on the electrical system must ONLY be
performed by qualified electricians or appropri-
ately trained and authorized personnel.
ALWAYS unplug the power plug before working
on the electrical equipment.
DANGER
Material damage due to incorrect mains voltage.
The machine can be significantly damaged or destroy by contact
with the incorrect mains voltage.
ONLY connect the machine to the specified mains voltage.
The machine is ONLY to be connected by qualified specialized
ATTENTION