For the 2-needle over lock machine , adjust both the
Ieft and right needles in the same manner.
Then, adjust traveling needle guard 1 so that the
clearance provided between the needle and the
blade point of lower looper should be0to0.05 mm
in the state where the needle is pushed to this side
by traveling needle guard 1 .
Adjust the lower looper so that the needle is pushed
by 0.05 to 0.1 mm to this side by the blade point of
lower lopper in the state where the blade point of lower
looper is aligned with the center of needle.
clearance provided between
needle and blade point of
lower looper
Push need to this side
Needle guard components
7704/7705/7714
7716
1
13