Programming instructions

6.3 Machine-specific setting and test programs ( + )
The machine-specific test programs are used to adjust and test the
individual machine components.
During the display of the DÜRKOPP-ADLER logo press the "Stop"
key followed by function key F2.
The display switches to the machine-specific test-program screen.
Select the required test program with cursor keys !" or """.
The symbol of the selected test program appears in reverse video.
Press the Enter key to run the selected test program.
6.3.1 Setting the machine type
This parameter is used to determine which folding-plate inserts are
used in the sewing machine.
type 1 dart length from 160 to 310 mm
type 2 dart length from 180 to 330 mm (standard)
type 3 dart length from 200 to 350 mm
type 4 dart length from 220 to 370 mm
STOP
4