Programming instructions
6.3 Machine-specific setting and test programs ( + )
The machine-specific test programs are used to adjust and test the
individual machine components.
–
During the display of the DÜRKOPP-ADLER logo press the "Stop"
key followed by function key F2.
The display switches to the machine-specific test-program screen.
–
Select the required test program with cursor keys ”!" or """.
The symbol of the selected test program appears in reverse video.
–
Press the Enter key to run the selected test program.
6.3.1 Setting the machine type
This parameter is used to determine which folding-plate inserts are
used in the sewing machine.
type 1 dart length from 160 to 310 mm
type 2 dart length from 180 to 330 mm (standard)
type 3 dart length from 200 to 350 mm
type 4 dart length from 220 to 370 mm
STOP
4
37