Programming instructions
Assign dart-length sizes
This parameter is used to assign dart-length sizes. Up to 5 sizes can
be entered for each dart length.
Procedure
–
When the main screen is displayed press function key
F2
.
The display switches to the ”sewing program” screen.
–
Select the "
size assignment
" parameter with cursor
keys ”!" or """.
The symbol of the selected parameter appears in reverse video.
–
Press Enter.
The dart-length window appears.
–
Select the required dart length with cursor keys ”#" or "$".
–
Press Enter.
The first size window appears in reverse video.
–
Enter the size (e.g. size 52).
–
Press Enter.
The size entered is saved in the table.
–
Select the next size window with the cursor key """.
–
Press Enter.
The second size window appears in reverse video.
–
If required, enter the next two sizes as described above.
–
Press the
F1
key to leave the assignment menu.
–
Press the
F1
key to leave the program-parameter menu.