Programming instructions

Sewing speed
Entry: 100 to 4800 rpm
Single step
This parameter is used to test and adjust the sewing machine quickly.
Sewing is halted at pre-set items.
Processing can be halted at any individual step by pressing the Stop
button.
Entry: on/off
Test seam
Entry: on/off
Select test seam with the Enter key.
The prompt to enter the code number appears in the display.
Enter the code number "
29801
" on the decimal keypad.
Once the correct number has been entered the test seam can be
switched on.
Side-seam commencement correction value
(only in the side-seam program)
This parameter equalises the distance from the centre of the needle to
the light barrier U1.
Entry: 0.0 mm - 25.0 mm
Side-seam end correction value
Jacket-breast dart seam-end correction value
This parameter indicates how many stitches are sewn after the
light-barrier signal.
Entry: 0 - 10 stitches
Dart-end correction value
(type 006 only)
This parameter indicates how many stitches are sewn after the
light-barrier signal.
Entry: 0 - 10 stitches
?
?
?