Group Number Description
6 Sewing motor error
1 Poor connection
2 Communication interrupted
3 Illegal command
4 Command buffer full
5 Protocol error
6 Timeout
7 Sending register 422
8 NAK
9 Drive not ready
10 UART not ready
11 Hardware error
50 Sewing motor timeout upon thread cutting
process
7 Internal errors
1 Contour data memory full.
The contour requires more than 1600 stitches.
2 Error upon cycle calculation.
Incorrect direction of rotation in the cycle, or
calculation overflow.
3 Error, NV-RAM data lost.
Default values are activated, reference
positions must be set again.
Call menus 301, 302 and 303.
4 Power fail input is activated.
Insufficient supply voltage to the sewing
machine.
10 Transponder errors
0 Zero-point gauge pin recognised, but
transponders could not be read.
1 Communication timeout Transponder reading
unit.
Communication with the transponder module is
disrupted. The module does not respond.
4 Transponder content is damaged. Incorrect
transponder checksum.
8 Communication error with the transponder
reading unit.
Transfer is disrupted. Incorrect transfer
checksum.