Programming instructions
4-19
1.7 Global parameters (F1)
These parameters can be modified before or during every sewing
process.
The new values apply however only after the next start of the entire
process.
–
Press the “F1” key.
The machine switches to ”global parameter" mode.
–
Select the desired submode by means of the “ ” or “ ” key.
Note
Press the “F4” key to reset all “global parameters” to the respective
default values.
List of setting menus
No. Setting
101 Piece counter
102 Setting of sewing motor speed
103 Setting of stitch length
104 Setting of template infeed
105 Setting of initial bartack
106 Setting of final bartack
107 Setting of initial stitch condensation
108 Setting of end stitch condensation
109 Switching on/off of thread monitor
110 Setting of reduced sewing speed
111 Setting of edge cutter speed
112 Setting of suction delay
1.7.1 Piece counter
The piece counter parameter can be reset to “0" by the operator.
Simultaneously, the counter in the main display (daily counter) is reset.
Operating steps
–
Select menu with the “ ” or “ ” key.
–
Press the “OK” key.
–
Press the “F4” key.
The counter is reset to “0".