Operating instructions
Controller with the OP3000 control panel
Operating Instructions 650-16 - 01.0 - 06/2014 77
7.6.1 Creating a program by keyboard input
1. Set all the parameters for each step.
2. Step through to the next step using the knee switch.
Cancel with ESC
Before the “S” key is pressed, program creation can be canceled
at any time by pressing the “ESC” key.
Once all steps are complete:
3. Press the “S” key.
The program is saved.
Depending on the settings at the technician level
• The sleeve side that was created is mirrored
• The sleeve side that was created is not mirrored
• The teach-in for the 2nd sleeve side is opened
• The selection screen for the action of creating the
2nd sleeve side is opened
The machine switches to Automatic mode.
The program that was just created is selected.
Thread tension
Value range: 0 to 99
• Use / to select the “Thread tension” parameter.
• Use / to change the thread tension.
Curve support
Value range: 0 to 6
• Use / to select the “Curve support” parameter.
• Use / to change the curve support.
Length of the current step in mm
Symbol Meaning