Operating instructions
Controller with the OP3000 control panel
Operating Instructions 650-16 - 01.0 - 06/201466
7.4 Manual mode
Figure 38: Parameters in manual mode
The following table shows the individual symbols (parameters) in
the display and the functions of the keys on the control panel.
When a parameter is selected, its color on the display changes.
When a parameter is changed, its new value is loaded immedi-
ately.
Symbol Meaning
(depending on the assignment)
Quick programming
• Press the upper softkey
Quick access function (softkey menu)
• Press the lower softkey,
7.4.1 Quick access func-
tion (softkey menu), page 68.
Program number
Value range: 000 to 999
Program 000 indicates that the controller is in
“Manual mode”.
• Use / to select the “Program” parameter.
• Use / to change the program number.
Or:
• Input the program number directly using the keys
“0” to “9” and confirm with “OK” as required.
This takes you into “Automatic mode”.
Fullness
Value range: Upper fullness: 0 to 16
Lower fullness: 0 to -6
• Use the keys “0” to “16” to select the desired value.
• Use the “+/-” key to select upper or lower fullness.
Or:
• Use the second pedal to select the fullness, if fitted.
Stitch length
Value range: 1.0 to 5.5 mm
• Use / to select the “Stitch length” parameter.
• Use / to change the stitch length