Operating instructions
Installation
Operating Instructions 650-16 - 01.0 - 06/201456
6.9.10 Connecting the equipotential bonding for the
knee switch
Figure 29: Connecting the equipotential bonding for the knee switch
Steps
1. Screw the protective earth conductor (3) (650 mm long) to the
attachment clip (1) on the knee switch.
2. Lay the cable in the cable duct (2) and plug the additional con-
troller on to the flat plug (4).
Danger of life-threatening electric shock
Disconnect the power plug before starting to
connect the equipotential bonding for the knee
switch.
Make sure the machine cannot be accidentally
switched back on.
DANGER
(1) - Mounting clip
(2) - Cable duct
(3) - Protective earth conductor
(4) - Tab connector
1
2
3
4