Operating instructions
Installation
Operating Instructions 650-16 - 01.0 - 06/201454
6.9.8 Connecting the equipotential bonding for the
additional controller
Figure 27: Connecting the equipotential bonding for the additional con-
troller
Steps
1. Plug the protective earth conductor (1) into the flat plug (2) on
the additional control cabinet.
2. Lay the cable (2) (300 mm long) to the control cabinet (3) and
screw it on.
Danger of life-threatening electric shock
Disconnect the power plug before starting to
establish equipotential bonding to the additional
controller.
Make sure the machine cannot be accidentally
switched back on.
DANGER
(1) - Protective earth conductor
(2) - Tab connector
(3) - Attachment to control cabinet
1
2
3