Operating instructions
4. Electrical connection
CAUTION:
The mains voltage must coincide with the rated voltage specified on
the name plate.
The machine adapts the local mains voltage via connection terminals 1
to 5 and A to D of the transformers in the control box.
Both the transformer terminals are factory-set to a mains voltage of
230 V.
For different mains voltages the terminals must be connected as
follows:
Strip terminal 2:
Voltage blue brown-and-white
200V A B
230V A C
240V A D
On strip terminal 5 the brown-and-white and blue-and-white wire
jumpers must be changed. Both connection terminals are given in the
table.
Example:
“L-4" means place the wire jumper between terminals L and 4.
Strip terminal 5:
Voltage brown-and-white blue-and-white
190V L - 4 N - 3
200V L - 4 N - 2
210V L - 4 N - 1
220V L - 5 N - 3
230V L - 5 N - 2
240V L - 5 N - 1
–
Undo screws 3.
–
Carefully remove the cover 4.
–
Check the configuration of the connections to the transformer
plug strips.
–
If necessary change the connections in line with the mains
voltage.
–
Re-attach the cover 4 with screws 3.