Operating instructions

34. Error Messages
Caution Risk of Injury!
Search for and remedy errors only in the “Safe Stop” position or with
the machine turned off.
No. Description Possible cause
Error remedy
134
135
136
Hardware error
Amplifier X-motor,
Y-motor, Z-motor
- Temperature too up
- Error 5V power supply
- Error 120V power supply
- Amplifier defective
- Check the temperature
- Check the fuses on the
transformer
- Replace the amplifier
141 Sewing motor controls:
Communication
interrupted
- Cable connections to the Efka
controls not okay
- Efka controls defective
- Check the cable connections
to the sewing motor controls
- Replace the Efka controls
143 Sewing motor controls:
Command buffer full
Internal error
Contact Dürkopp-Adler Service
148 Sewing motor
controls:
Drive not ready
- Cable connections to the Efka
controls not okay
- Efka controls defective
- Check the cable connections to
the sewing motor controls
- Replace the Efka controls
149 Sewing motor controls:
UART not ready
- CPU unit defective
- Replace the CPU unit
150 Sewing motor
controls: Hardware
error
- Hardware error Efka controls
- Internal error
- Synchronizer not connected
or defective
- Commutation initiator - Lead
or voltage changer faulty
- Mains voltage too down
- Blockage, motor mechanically
overloaded
- 1 revolution after initial point
run-up reset pulse not registered
or
synchronizer defective
- Parameter not present or
internal error
- Transmission temporarily
interrupted
- Belt jumped off or defective
- Replace the Efka controls
- Contact Dürkopp-Adler
Service
- Positionsgeberanschluß prüfen
- Check the synchronizer
connection
- Check the setting for the mains voltage
- Check the mechanics
- Check the synchronizer (clearance
to the disc)
Replace the synchronizer
- Contact Dürkopp-Adler Service
- Check the cable connection to the
Efka controls
- Check the belt
182 False data checksum
in the data memory
Turn the machine off and on again.
Data is automatically reset to factory
settings.
201 Data not present Internal error
Contact Dürkopp-Adler Service
208
209
Step losses in the
lateral motion axis
Lateral motion axis too sluggish or
collision of components
Check the mechanics
Conduct a step loss test
210
211
Step losses in the
longitudinal motion
axis
Longitudinal motion axis too
sluggish or collision of components
Check the mechanics
Conduct a step loss test
212
213
Step losses in the
sewing mechanism
rotation axis
Sewing mechanism rotation axis
too sluggish or collision of
components
Check the mechanics
Conduct a step loss test
79