Operating instructions
Correction
Height of the thread catcher and clearance of the thread catcher to
the needle
–
Loosen screws 5 and 6.
–
Adjust the height of thread catcher unit.
The clearance to the needle bar guide must be 2 mm.
–
Tighten screws 5 and 6.
–
Set the clearance to the needle through the stop screw 12.
The clearance from the thread catcher to the needle must be
approx. 7-8 mm (dimension X). The clearance to the needle can in
some cases also deviate slightly from this value.
Lower position of the thread catcher
–
Loosen the lock nut above the knurled screw 8.
–
With the knurled screw 8, set the lower position of the thread
catcher.
–
The clearance between the thread catcher and the material must
be approx. 3 mm.
–
Manually press the thread catcher down and check the position of
the thread catcher.
–
Tighten the lock nut above the knurled screw 8.
Lateral position of the thread catcher
–
Loosen screws 7.
–
Set the lateral clearance of the thread catcher.
–
Tighten screws 7.
46
12