Operating instructions

Correction
Height of the thread catcher and clearance of the thread catcher to
the needle
Loosen screws 5 and 6.
Adjust the height of thread catcher unit.
The clearance to the needle bar guide must be 2 mm.
Tighten screws 5 and 6.
Set the clearance to the needle through the stop screw 12.
The clearance from the thread catcher to the needle must be
approx. 7-8 mm (dimension X). The clearance to the needle can in
some cases also deviate slightly from this value.
Lower position of the thread catcher
Loosen the lock nut above the knurled screw 8.
With the knurled screw 8, set the lower position of the thread
catcher.
The clearance between the thread catcher and the material must
be approx. 3 mm.
Manually press the thread catcher down and check the position of
the thread catcher.
Tighten the lock nut above the knurled screw 8.
Lateral position of the thread catcher
Loosen screws 7.
Set the lateral clearance of the thread catcher.
Tighten screws 7.
46
12