Instruction manual

Select the individual seam sections by clicking on them and enter
the corresponding seam parameters.
The selected seam segment is displayed with a raised bar.
monitored (red) not monitored
(green)
selected
seam section
Parameter Description
Free/SAB Indicates whether a free seam segment
or a tearing seam is activated
Max. speed maximum speed for the current seam segment
Stitch length stitch length for the current seam segment
St l corr.fac. Correction of the stitch length depending
on the material
Dist. Length Distance between the two strips on the
sewing material
Thread tension Tolerance range (lower value, top value)
and number of tolerance stitches
Thread tens. Value of power supply in % (only with ETT)
Stop at strip, stitch counting or manually (Pedal 2)
GB thread ten.
Komp file Selection of a Teach-in file (only with ETT)
Lift Stroke Lift stroke of the alternating sewing feet
Lift stroke knee Lift stroke upon activating the knee lever
(Rapid stroke adjustment)
Bartack stitches Number of bartack stitches
(forwards/backwards)
Sewing in the label Activates the seam scanner
TT ON/OFF Trims the thread at the end of the seam
section
After setting the seam parameters for all of the seam sections,
press the button “Save”.
60