Operating instructions

5. Lubrication
5.1 Topping up with oil
Top up the oil reservoir using DA-10 lubricating oil or only or an
equivalent oil with the following specification:
Viscosity at 40°C: 10 mm
2
/s
Flashpoint: 150 °C
DA-10 is available from DÜRKOPP ADLER AG r eta il ou tl ets
(see operating instructions).
Unscrew the oil-filler cap 2 and top up with oil.
Check the oil level at sight glass 1.
The oil level must be between EMPTY und FULL.
Replace the oil-filler cap 2.
Remove any oil which has overflowed into the oil collector.
5.2 Adjusting hook lubrication
CAUTION:
In order to ensure that the hook is properly lubricated during the
running-in period, a relatively large quantity of oil is set prior to
despatch.
This setting should be checked and adjusted after the running-in
period.
See also the Operating or Service instructions.
2
11
21