Operating instructions

5.5.14 Selection of the Pedal Mode for the Fullness Adjustment
This setting is only effective in the “Manual” function screen (Chapter
5.2).
In all other operation modes only a
fullness correction
in steps of +/- 0.5 can be conducted with the pedal.
Fullness adjustment pedal mode for manual sewing :
Correction value +/- 0.5
Continuous 0 ... 15
Continuous 0 ... 7
Continuous 7.5 ... 15
/ Parameter selection
Confirmation of the parameter selection