4.3.4 Automatic Check of the Inputs
In this test program, the complete input picture is monitored for
changes. With a change, the input number and the switching status
are displayed.
Example:
Operate knee switch (input no.7) ð Status “+”
Release knee switch (input no. 7) ð Status “-”
Illus. 4.3.4-1 Indicator screen - Input test
Input assignment with Cl. 550-16-26:
Input Designation
7Kneeswitch
The “Input Te st” function screen is exited again v ia the soft key “F1".
Entry : Close window
Close the “Input Test” function screen