Operating instructions
4.2.3 Check Program for the Analog/Digital Converter
The general functioning of the analog/digital converter is checked with
the check program. It must be possible to change the value shown in
the screen and in the segment display with the left additional pedal for
the bunching value change.
Illus. 4.2.3-1 Indicator screen for the analog/digital converter check program
Indicator screen-Analog/digital converter check program
Segment display-Analog/digital converter-Test
The
“Analog/Digital Converter Test” function screen is exited again v ia the
soft key “F1”.
Entry : Close window
Close the “Analog/Digital Converter Test ” function screen