Operating instructions

4.2.2 Setting Program for the Additional Pedal - Bunching Value Change
The left additional pedal for the bunching value change is set with this
program.
Illus. 4.2.2-1: Indicator screen for the pedal test
Order of operations:
Display:
Step the foot pedal completely forward.
Operate the knee switch.
The first measured value is established and displayed in the
screen (e.g. 127).
Display:
Step the foot pedal back to the neutral position.
Operate the knee switch.
The second measured value is established and displayed in the
screen (e.g. 760).
Display:
Step completely back on the foot pedal.
Operate the knee switch.
The third measured value is established and displayed in the
screen
(e.g. 820).
The measured values are checked for plausibility.