4.2.2 Setting Program for the Additional Pedal - Bunching Value Change
The left additional pedal for the bunching value change is set with this
program.
Illus. 4.2.2-1: Indicator screen for the pedal test
Order of operations:
Display:
–
Step the foot pedal completely forward.
–
Operate the knee switch.
–
The first measured value is established and displayed in the
screen (e.g. 127).
Display:
–
Step the foot pedal back to the neutral position.
–
Operate the knee switch.
–
The second measured value is established and displayed in the
screen (e.g. 760).
Display:
–
Step completely back on the foot pedal.
–
Operate the knee switch.
–
The third measured value is established and displayed in the
screen
(e.g. 820).
–
The measured values are checked for plausibility.