Operating instructions

5.2 Plug connections at the multiple pin strip (15-fold)
Connect the plug connections of the button
sewing automat, the control panel and the
reference value transmitter as follows:
Plug light barrier /sensor to plug
connection 1 (REF-signals)
Note: The 8-pole plug is encoded.
Plug magnets to plug connection 5 (PWM)
Note: The 8-pole plug is encoded.
Plug encoder signal sewing motor to plug
connection 2 (encoder sewing motor)
Plug control panel to plug connection 3
(control panel)
Plug operating elements (pedal switch)
via adapter 6 to plug connection 4
(I/O 1-8)
2
15
5
6
1
2
3
4