Operating instructions
3.4 Connect the control box to the main switch
ATTENTION !
Any kind of work on the electric equipment of the automatic bartacker
must be carried out only by electricians or trained personnel.
The mains plug has to be pulled out!
–
Take off the switching k nob 1.
For this purpose loosen the screw 2 in the knob.
–
Remove the cover 3 from the main switch.
For this purpose unlock the locking bar in drill-hole 4 with a
screwdriver.
–
Run the cable from the control box into the cable duct.
–
Insertthecableinthemainswitch.
–
Connect the cable cores of the control box to the
screws ”T1” and “T2”.
–
Connect the protective conductor of the control box in
themainswitch.
–
Put the cover on the line switch again.
–
Put on the switching knob 1 and screw it tight.
–
Put on the cover of the cable duct.