Operating instructions
6
4. Pneumatic Connection
For the operation of the clamp lifting, thread tension opening, needle
cooling, etc. the unit must be supplied with water-free compressed air.
ATTENTION !
For a flawless functioning of the pneumatic control processes the
compressed air supply must be laid out as follows:
Even at the instant of greatest air consumption the minimum operating
pressure may not fall below 5bar.
Connecting the compressed air maintenance unit
–
Connect the connection hose 3 for the maintenance unit to the
compressed air supply with the enclosed c oupling.
Setting the operating pressure
–
The operating pressure is 6bar.
It can be seen on the pressure gauge 2.
–
For setting the operating pressure pull knob 1 up and turn.
Turning clockwise = Increase pressure
Turning counterclockwise = Decrease pressure
1
2
3