Operating instructions
7.4 "Operator Level" Parameter List:
Parameter Function Setting
Max. Min. Ex works
000 Arv
Beginning bartack stitches-forward 254 0 2
001 Arr
Beginning bartack stitches-reverse 254 0 4
002 Err
End bartack stitches-reverse 254 0 3
003 Erv
End bartack stitches-forward 254 0 3
004 LS
Light barrier compensation stitches * 254 0 4
005 LSF
Number of stitches of the light barrier filter 254 0 0
for knit goods *
006 LSn
Number of light barrier seams * 15 1 1
007 Stc
Number of stitches of a seam with stitch
counting * 254 0 10
008 F
Assignment to key 3 of a 5 1 2
parameter from the technician level
1 = Soft start ON / OFF
2 = Fancy stitch bartack ON / OFF
3 = Stroke adjustment locking = ON
Stroke adjustment tentative = OFF
4 = Needle cooling ON / OFF
5 = Turning back ON / OFF
009 LSI
Sensitivity setting 255 0 16
of the continuous beam light barrier *
010 cLS
PEC compensation stitches with stitch
shortening * 254 0 8
080 Sav
Number of stitches-beginning fancy bartack
forward 254 0 3
081 SAR
Number of stitches-beginning fancy bartack
reverse 254 0 3
082 Ser
Number of stitches-end fancy bartack reverse 254 0 3
083 Sev
Number of stitches-end fancy bartack forward 254 0 3
085 cFW
Number of stitches of the remaining thread
monitor count * 2540 0 0
* = Key function is not assigned in this machine class.
ATTENTION !
Several parameters at the technician level must be
appropriately set for classes
381
and
382
.
See Installation Instructions Chapter 6.10.
26