8.2 Operation of the 6F82FA sewing-drive control
8.2.1 Operating elements in the 6F82FA sewing-drive control
8.2.2 Key functions in the 6F82FA sewing-drive control
Functions can be turned on and off by briefly pressing the keys on the
operating panel. The functions are effective on the machine only if the
relevant devices (e.g. magnetic or electro-pneumatic sewing-foot lift)
are present.
Key Function Display
S1 programming mode on/off
S2 double starting bar tack
starting bar tack off
single starting bar tack
LED 2 on, LED 1 off
both LEDs off
LED 1 on, LED 2 off
S3 double ending bar tack
ending bar tack off
single ending bar tack
LED 4 on, LED 3 off
both LEDs off
LED 3 on, LED 4 off
S4 auto. foot lift on halt in seam
no auto. foot lift on halt in seam
auto. foot lift after thread cut
no auto. foot lift after thread cut
LED 5 on
LED 5 off
LED 6 on
LED 6 off
S5 basic needle position = down
basic needle position = up
LED 7 on, LED 8 off
LED 8 on, LED 7 off
8.2.3 Changing operator-level parameter values
The operator-level parameters are in the parameter list (see section
7.4).
Turn on the main switch.
Press the P k ey. The first operator-level parameter 000 is
displayed.
Press the +”or“- keys to move to the next or preceding
para me ter.
Press the E k ey. The value of the selected parameter is
displayed.
The parameter value can be changed with the + and -”keys.
Press the E k ey to save the change and display the next
para me ter,
or press the P key twice to save the change and leave
programming level.